Heat eksenja bilong HVAC

Heat eksenja bilong HVAC

HVAC plet hit eksenja em i wanpela hai-efisiensi hit eksenja divais we ol i wokim stret long ol HVAC sistem. Em
i winim hariap senis bilong hat bilong kol na hatpela samting long rot bilong wokim wanpela liklik rot bilong ron i go insait long
ol plet ain i gat 'corrugated'. Em i gat ol gutpela samting olsem sevim pawa, fleksibel, na sefti, na em i stap long planti hap
i stret long 'temperature regulation' na 'energy recovery' nid long ol kain kain wok olsem ol sivil bilding,
indastriel prodaksen, hot wara saplai, na nupela eneji.
Askim wok painimaut
modular-1
Mining bilong Prodak

Wanpela 'heat exchanger' em i wanpela 'high-efficiency heat exchange device we ol i wokim bilong hatim, ventilesen, na ea kondisen (HVAC) sistem. Em i save mekim hat i go namel long ol hot na kol wara long rot bilong wanpela hat eksens kor we i gat ol 'stamped corrugated metal plates' we ol i putim na pasim wantaim. As tingting bilong en em long yusim ol liklik rot bilong ron namel long ol plet long larim kol na hat midia i ron long narapela narapela o i go het, na long senisim hat hariap tru long bikpela konduktiviti bilong metal plet. Dispela ikwipmen i inapim ol nid bilong kisim bek pawa na 'temperature regulation' bilong ol HVAC sistem, olsem hatim, kol, na hat wara saplai, na em i wanpela bikpela samting bilong kamapim gutpela yusim bilong pawa insait long HVAC enjiniaring.

1

Ol samting bilong prodak

 

1.Hai-efisienssenis bilong hatna bikpela yusim bilong eneji: Spesel straksa bilong ol 'corrugated plates' i save kamapim strongpela 'turbulence' insait long 'flow channel', we i save helpim tru 'heat transfer coefficient' (K veliu). Het trensfer efisiens em 3-5 taims bilong ol tradisenel 'shell' na 'tube heat exchanger'. Em inap long senisim hat hariap wantaim liklik senis long tempereja, daunim wes bilong pawa, na helpim sistem long sevim pawa.

2.Smolpela straksa na liklik hap graun:Ol plet i gat wanpela 'densely stacked design', na 'heat exchange area' long wan wan yunit volium inap long kamap 5-10 taims bilong ol 'shell' na 'tube heat exchanger'. Aninit long wankain 'heat exchange requirements', volium bilong ol ikwipmen em 1/3-1/5 tasol bilong ol tradisenel 'heat exchanger', na hevi bilong en i no hevi tumas, na dispela i mekim isi long putim insait long ol masin rum, siling o ol 'equipment mezzanine' we i no gat planti spes, na dispela i daunim pe bilong sivil enjiniaring na putim.

3.Fleksibel ekspansen na strongpela adaptebiliti:Long rot bilong yusim wanpela 'modular assembly' rot, ol i ken skruim sistem bihainim ol senis long HVAC sistem lod (olsem putim ol nupela eria long bilding o stretim ol bikpela lod) long rot bilong skruim o daunim namba bilong ol 'heat exchange panel' o putim ol 'heat exchange units'. Dispela i rausim nid long senisim olgeta sistem, na i stret long wok konstraksen na bihain wok bilong stretim ol projek we i gat kain kain sais.

Liklik resistans lus na liklik operesen kos:Gutpela 'flow channel' disain i daunim 'fluid flow resistance' na i daunim 'energy consumption' bilong 'circulating water pump'; long wankain taim, gutpela plet pes i no inap long bruk, na dispela i mekim na i gat longpela taim bilong lukautim na isi long klinim (ol i ken rausim na wasim straksa), na dispela i daunim ol kos bilong operesen na mentenens bilong sistem.

5.Seif, yu ken trastim, na i save stap longpela taim:Ol i wokim ol panel long ol samting we i no inap bagarap olsem 304/316L 'stainless steel' na 'titanium alloy', na ol 'gasket' em ol i wokim long 'food-greid raba o 'fluororubber'. Ol i gat bikpela mak bilong hat (-40 digri ~180 digri) na strongpela presa resistens (inap long 2.5MPa), na dispela i mekim ol i ken bihainim ol hevi wok kondisen bilong ol HVAC sistem. Sevis laip bilong ol inap long 10-15 yia.

Em i no bagarapim envairomen na i no gat polusen:Ol kol na hatpela midia i stap wanpis olgeta long taim bilong senisim hat, na dispela i rausim hevi bilong kros-kontaminesen. Dispela i inapim ol bikpela klinpela rikwaemen bilong ol aplikesen olsem domestik hot wara saplai na HVAC sistem insait long ol medikel fasiliti. Long wankain taim, bikpela strong bilong kisim bek eneji i save daunim yusim bilong ol fosil fiul na kabon emisen, na i bihainim ol lo bilong grinpela bilding na lukautim envairomen.

 

Ol wok bilong prodak

Bikpela wok bilong senisim hat

Olsem wanpela "eneji trensfe stesin" insait long HVAC sistem, em i save mekim gutpela hat trensfe namel long kol na hatpela midia. Olsem, insait long wanpela sistem bilong hatim haus, em i save salim hat i kam long hai-temperature hot wara we boiler i kamapim i go long wara i raun insait long haus; insait long wanpela 'cooling system', em i save senisim hat bilong 'low-'temperature kol wara we 'chiller' i kamapim i go long 'indoor return air', na long dispela rot em i save mekim 'cooling' i kamap.

01

Kisim bek na yusim pawa

Kisim bek ol pipia hat o kol long ol HVAC sistem long mekim gutpela wok long eneji. Olsem, kisim bek kol (sama) o hat (winta) bilong ea kondisen eksos long pre-tritim fres win na daunim hevi long ea kondisen yunit; kisim bek ol pipia hat long ol pipia wara bilong ol indastri na ges bilong paia bilong hatim ol haus o hatim wara bilong ol haus, na dispela i daunim yusim bilong eneji.

02

Gutpela kontrol bilong tempereja

Long rot bilong stretim 'medium flow rate' o 'heat exchange area' bilong ol plet, ol i ken bosim gut 'temperature' bilong 'output medium' long inapim ol 'temperature requirements' bilong HVAC sistem aninit long ol narapela narapela wok kondisen. Olsem, bihainim ol bekim i kam long ol 'indoor temperature sensors', ol i ken stretim 'heat exchange efficiency' bilong mekim temperaja insait long haus i stap wankain insait long mak we ol i makim (olsem, 18-22 digri long taim bilong kol, 24-26 digri long taim bilong san).

03

Proteksen bilong sistem na gutpela wok

Em i gat gutpela 'anti-scaling' na 'anti-'korosen samting, na i save daunim 'system blockage' na 'equipment wear', na i save mekim HVAC sistem i wok gut longpela taim; sampela model i gat ol intafes bilong sekim tempereja na presa, we ol i ken bungim wantaim kontrol sistem long kamapim ol alam bilong ova-temperature na ova-presa, na dispela i mekim sistem i wok gut.

04

Hot na kol wara seperesen na aisolesen

Dispela i mekim na ol i ken stap wanpis namel long ol hot na kol midia, na i stopim kros-kontaminesen namel long ol narapela narapela midia na tu i inapim ol tempereja rikwaemen bilong ol narapela narapela lup insait long sistem. Olsem, taim hot wara bilong haus na wara bilong hatim haus i gat wankain hat sos, wanpela plet hit eksenja i save separetim tupela midia, na mekim hot wara bilong haus i stap klin na i no bagarapim presa na tempereja stebiliti bilong hiting sistem.

05

Skop bilong Aplikesen
 
 
 

Insait long sivil bilding sekta

Dispela i gat ol kain kain sivil na pablik bilding olsem ol residensiel komyuniti, ol opis bilding, ol soping mol, ol hotel, ol haus sik, ol skul, na ol haus bilong ol lapun. Em i ken wok wantaim ol 'centralized heating/cooling' sistem, ol 'air conditioning' na 'ventilation' sistem, na ol 'centralized' o wanwan 'domestic hot water supply' sistem bilong inapim ol 'temperature regulation' bilong bilding na ol nid bilong yusim hot wara.

 
 

Indastrial prodaksen sekta

Em i gutpela long ol ea kondisen na kol sistem insait long ol woksop bilong faktori, ol kol sistem bilong ol prodaksen ikwipmen, na ol nid bilong proses kol/hiting insait long ol indastri olsem ol marasin, ilektroniks, na prosesing bilong kaikai. Em i ken yusim tu long kisim bek hat bilong ol pipia wara na ges bilong ol indastri, na dispela i mekim na ol i ken yusim sekenderi eneji na daunim yusim bilong eneji long prodaksen.

 
 

Long sait bilong nupela eneji na lukautim envairomen

Em i wanpela 'core heat exchange unit' we i gutpela long ol nupela eneji sistem olsem ol 'ground source heat pump', 'air source heat pump', na sola hiting. Em i ken yusim tu long ol samting olsem 'precision air conditioning cooling' bilong ol 'data center server rooms' na 'energy recovery' insait long ol grinpela bilding, na dispela i helpim long lukautim envairomen, sevim eneji, na 'low-carbon operesen.

 
 

Ol spesel aplikesen eria i gat

kontrol bilong tempereja insait long ol 'cold chain logistics' warehaus, senis bilong hat insait long ol stesin na karis bilong tren (subway, hai-spid tren), na HVAC na hot wara saplai sistem bilong ol sip na ol pletfom long solwara, na stretim long tempereja kontrol na eneji trensfe nid long ol spesel envairomen.

 
Anyang Tengrui Energy Saving Equipment Co., Ltd.

Sapos yu laik save moa long ol 'heat exchanger units' o yu laik baim, plis salim wanpela email i go long9988xiaoshuai@gmail.com, mipela bai bekim yu long taim stret bihain long mipela i lukim dispela toksave!

Profesenel tim

29,000+ saveman long wol
Ol senia projek menesa i save bosim gut olgeta samting bilong projek

7x24 aua deliveri

Kampani bilong mipela i save givim fri teknikel sapot long ol prodak mipela i salim na i save oganaisim teknikel trening bilong ol wokmanmeri.

back
 

Kontektim nau

Hot Tag: Hit eksenja bilong HVAC, Saina Het eksenja bilong HVAC manifakta, saplaia, faktori